产品中心
PRODUCTS
|
product description:
ZW20-12F(M) outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker is an outdoor high-voltage switchgear with a rated voltage of 12kV and three-phase AC 50/60Hz. It is mainly used for breaking and closing the load current, overload current and short-circuit current of the power system.
ZW20-12F(M) outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker is an outdoor high-voltage switchgear with a rated voltage of 12kV and three-phase AC 50/60Hz. It is mainly used for breaking and closing the load current, overload current and short-circuit current of the power system. It is suitable for protection and control of substations, industrial and mining enterprises, and urban and rural distribution networks, especially for places with frequent operations and urban network automation distribution networks. This product is matched with the controller to meet the requirements of the distribution automation system and can reliably and effectively complete the traditional recloser function. It adopts a mature box-type sealing structure with good sealing performance, which makes it unaffected by the external environment and is a maintenance-free product. Its spring operating mechanism or permanent magnet operating mechanism has high action reliability and is an excellent product for pole-mounted circuit breakers.
Conditions of Use
◆ Working environment temperature: not exceeding 40℃; daily average temperature not exceeding 35℃; minimum ambient air temperature is -25℃;
◆ Relative humidity of air: daily average value is not more than 95%, monthly average value is not more than 90%; daily average value of water vapor pressure is not more than 2.2kPa, monthly average value is not more than 1.8kPa;
◆ Altitude: no more than 2000m;
◆ The surrounding area is not obviously polluted by dust, smoke, corrosive and/or flammable gas, steam or salt mist;
◆ Vibration or ground motion from outside the switchgear and control equipment is negligible;
◆ The amplitude of induced electromagnetic interference in the secondary system shall not exceed 1.6kV.
Main technical parameters of circuit breakers
Appearance and installation dimensions (mm)

Features
◆ Miniaturized design;
◆ The box has an inverted structure, is fully sealed, has a simple sealing effect, and has a high anti-fouling level;
◆ The transmission method is novel, simple and reliable;
◆ The main components are sealed in the box to achieve true maintenance-free;
◆ Voltage transformer and isolating switch can be installed externally.